About Your System

59

The memory

configuration is

not optimal. The

recommended

memory

configuration

is:

<message>

Invalid memory

configuration. The system

will run but with reduced

functionality.

Ensure that the memory

modules are installed in a

valid configuration. See

"General Memory Module

Installation Guidelines" on

page 92. If the problem

persists, see

"Troubleshooting System

Memory" on page 181.

Write fault

Write fault on

selected drive.

Faulty USB device, USB

medium, optical drive

assembly, hard drive, or hard-

drive subsystem.

Replace the USB medium or

device. Ensure that the USB,

SAS backplane, or SATA

cables are properly

connected. See

"Troubleshooting a USB

Device" on page 174,

"Troubleshooting an Internal

USB Key" on page 183, and

"Troubleshooting a Hard

Drive" on page 186.

Warning: QPI

links operating

in Slow Speed

Mode.

The processor has bent pins.
The processor is not properly

seated on the processor

socket.

Verify that there are no bent

pins on the processor. If the

processor has bent pins, see

"Getting Help" on page 203.
Reseat the processors. See

"Removing a Processor" on

page 147 and "Installing a

Processor" on page 151.
If the problem persists, see

"Getting Help" on page 203.

Warning: QPI link

between <Agent X>

Port <Y> and

<Agent X1> <Port

Y1> failed.

Warning: QPI link

between <Agent X>

Port <Y> and

<Agent X1> <Port

Y1> degraded to

half-width.

NOTE:

For the full name of an abbreviation or acronym used in this table, see the

Glossary

at dell.com/support/manuals.

Message

Causes

Corrective Actions

book.book Page 59 Tuesday, December 4, 2012 3:11 PM