55

SATA port

x

device auto-

sensing error

SATA port

x

device

configuration

error.

SATA port

x

device error

The drive connected to the

specified SATA port is faulty.

Replace the faulty drive.

Sector not found

Seek error

Seek operation

failed

Faulty hard drive, USB

device, or USB medium.

Replace the USB medium or

device. Ensure that the USB

or SAS backplane cables are

properly connected. See

"Troubleshooting a USB

Device" on page 174 or

"Troubleshooting a Hard

Drive" on page 186 for the

appropriate drive(s) installed

in your system.

Shutdown failure

General system error.

See "Getting Help" on

page 203.

The amount of

system memory has

changed.

Memory has been added or

removed or a memory

module may be faulty.

If memory has been added or

removed, this message is

informative and can be

ignored. If memory has not

been added or removed,

check the SEL to determine

if single-bit or multi-bit

errors were detected and

replace the faulty memory

module. See

"Troubleshooting System

Memory" on page 181.

Time-of-day

clock stopped.

Faulty battery or faulty chip. See "Troubleshooting the

System Battery" on page 178.

Message

Causes

Corrective Actions