About Your System

Alert! iDRAC6 not

responding.

Power required

may exceed PSU

wattage.

Alert!

Continuing

system boot

accepts the risk

that system may

power down

without warning.

The iDRAC6 is hung.
The iDRAC6 was remotely

reset while system was

booting
After AC recovery, the

iDRAC6 takes longer than

normal to boot.

Remove AC power to the

system for 10 seconds and

restart the system.

Alert! Node

Interleaving

disabled! Memory

configuration

does not support

Node

Interleaving.

The memory configuration

does not support node

interleaving, or the

configuration has changed

(for example, a memory

module has failed) so that

node interleaving cannot be

supported.

The system will

run but without node

interleaving.

Ensure that the memory

modules are installed in a

configuration that supports

node interleaving. Check

other system messages for

additional information for

possible causes. For memory

configuration information,

see "General Memory

Module Installation

Guidelines" on page 92. If

the problem persists, see

"Troubleshooting System

Memory" on page 181.

Message

Causes

Corrective Actions