Dell PowerEdge R910 User Manual

Page 40

Advertising
background image

40

About Your System

W1101

CPU VCACHE

Regulator

temp

exceeding

range. Check

fans.

The regulator temperature

has reached a point outside

of the allowed range.

See "Troubleshooting

System Cooling

Problems" on page 180. If

the problem persists, see

"Getting Help" on

page 203.

W1102

Mem Voltage

Regulator

temp

exceeding

range. Check

fans

The regulator temperature

has reached a point outside

of the allowed range.

See "Troubleshooting

System Cooling

Problems" on page 180. If

the problem persists, see

"Getting Help" on

page 203.

W1228

RAID

Controller

battery

capacity <

24hr.

Warns predictively that the

RAID battery has less than

24 hours of charge left.

Allow RAID battery to

charge to greater than 24

hours of sustained charge.
If problem persists,

replace the RAID battery.

See "Installing the RAID

Battery" on page 146.

W1627

Power

required >

PSU wattage.

Check PSU and

config.

The system configuration

requires more power than

what the power supply can

provide.

Turn off power to the

system, reduce the

hardware configuration or

install higher-wattage

power supplies, and then

restart the system.

W1628

Performance

degraded.

Check PSU and

system

configur-

ation.

The system configuration

requires more power than

what the power supply can

provide, but it can boot if

throttled.

Turn off power to the

system, reduce the

hardware configuration or

install higher-wattage

power supplies, and then

restart the system.

Code

Text

Causes

Corrective Actions

book.book Page 40 Tuesday, December 4, 2012 3:11 PM