Troubleshooting a storage controller – Dell PowerEdge R910 User Manual

Page 187

Advertising
background image

Troubleshooting Your System

187

2 If applicable, remove the bezel. See "Removing the Front Bezel" on

page 87.

3 If your system has a RAID controller and your hard drives are configured in

a RAID array, perform the following steps.

a

Restart the system and enter the host adapter configuration utility

program by pressing <Ctrl><R> for a PERC controller or

<Ctrl><C> for a SAS controller.
See the documentation supplied with the host adapter for information

about the configuration utility.

b

Ensure that the hard drive(s) have been configured correctly for the

RAID array.

c

Take the hard drive offline and reseat the drive. See "Removing a Hard

Drive" on page 109.

d

Exit the configuration utility and allow the system to boot to the

operating system.

4 Ensure that the required device drivers for your controller card are installed

and are configured correctly. See the operating system documentation for

more information.

5 Restart the system, enter the System Setup program, and verify that the

controller is enabled and the drives appear in the System Setup program.

See "Using the System Setup Program and UEFI Boot Manager" on

page 63.
If the problem persists, see "Troubleshooting a Storage Controller" on

page 187.

Troubleshooting a Storage Controller

NOTE:

When troubleshooting a SAS or PERC controller, also see the

documentation for your operating system and the controller.

1 Run the appropriate online diagnostic test. See "Using Online Diagnostics"

on page 193.

2 Enter the System Setup program and ensure that the SAS or PERC

controller is enabled. See "Using the System Setup Program and UEFI

Boot Manager" on page 63.

book.book Page 187 Tuesday, December 4, 2012 3:11 PM

Advertising