Dell PowerEdge R910 User Manual

Page 35

Advertising
background image

About Your System

35

E1A15

SAS cable B

failure.

Check

connection.

SAS cable B is missing or

bad.

Reseat the cable. If the

problem persists, replace

cable.
If the problem persists,

see "Getting Help" on

page 203

E1A1D

Control panel

USB cable not

detected.

Check cable.

USB cable to the control

panel is missing or bad.

Reseat the cable. If the

problem persists, replace

cable.
If the problem persists,

see "Getting Help" on

page 203.

E2010

Memory not

detected.

Inspect

DIMMs.

No memory was detected in

the system.

Install memory or reseat

the memory risers and

memory modules. See

"Installing a Memory

Riser" on page 101,

"Installing Memory

Modules" on page 102 or

"Troubleshooting System

Memory" on page 181.

E2011

Memory

configuratio

n failure.

Check DIMMs.

Memory detected, but is not

configurable. Error detected

during memory

configuration.

See "Troubleshooting

System Memory" on

page 181.

E2012

Memory

configured

but unusable.

Check DIMMs.

Memory configured, but is

unusable.

See "Troubleshooting

System Memory" on

page 181.

E2013

BIOS unable

to shadow

memory. Check

DIMMs.

The system BIOS failed to

copy its flash image into

memory.

See "Troubleshooting

System Memory" on

page 181.

Code

Text

Causes

Corrective Actions

book.book Page 35 Tuesday, December 4, 2012 3:11 PM

Advertising