About Your System

39

E2112

Memory spared

on Card x

DIMM ##.

Power cycle

AC.

The system BIOS spared the

memory because it has

determined the memory has

too many errors.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Troubleshooting

System Memory" on

page 181.

E2113

Mem mirror

OFF on DIMM

## & ##.

Power cycle

AC.

The system BIOS disabled

memory mirroring because

it has determined one half

of the mirror has had too

many errors. "## & ##"

represents the memory

module pair implicated by

the BIOS.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Troubleshooting

System Memory" on

page 181.

I1910

Intrusion

detected.

Check chassis

cover.

System cover has been

removed.

Information only.

I1911

LCD Log Full.

Check SEL to

review all

Errors.

LCD overflow message. A

maximum of ten error

messages can display

sequentially on the LCD.

The eleventh message

instructs the user to check

the SEL for details on the

events.

Check the SEL for details

on the events.
Remove AC power to the

system for 10 seconds or

clear the SEL.

I1912

SEL full.

Review &

clear log.

The SEL is full of events

and is unable to log any

more.

Check the SEL for more

information and then

clear the SEL.

W1100

CPU VCORE

Regulator

temp

exceeding

range. Check

fans.

The regulator temperature

has reached a point outside

of the allowed range.

See "Troubleshooting

System Cooling

Problems" on page 180. If

the problem persists, see

"Getting Help" on

page 203.

Code

Text

Causes

Corrective Actions

book.book Page 39 Tuesday, December 4, 2012 3:11 PM