Removing lcd status messages, Table 1-1. lcd status messages – Dell PowerEdge R910 User Manual

Page 24

Advertising
background image

24

About Your System

Removing LCD Status Messages

For faults associated with sensors, such as temperature, voltage, fans, and so

on, the LCD message is automatically removed when that sensor returns to a

normal state. For other faults, you must take action to remove the message

from the display:

• Clear the SEL — You can perform this task remotely, but you will lose the

event history for the system.

• Power cycle — Turn off the system and disconnect it from the electrical

outlet; wait approximately 10 seconds, reconnect the power cable, and

restart the system.

NOTE:

The following LCD status messages are displayed in the simple format. See

"Setup Menu" on page 16 to select the format in which the messages are displayed.

Table 1-1. LCD Status Messages

Code

Text

Causes

Corrective Actions

E1000

Failsafe

voltage

error.

Contact

support.

Check the SEL for critical

failure events.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 203.

E1114

Ambient Temp

exceeds

allowed

range.

Ambient temperature has

reached a point outside of

the allowed range.

See "Troubleshooting

System Cooling

Problems" on page 180.

E1116

Memory

disabled,

temp above

range. Power

cycle AC.

Memory has exceeded

allowable temperature and

has been disabled to prevent

damage to the components.

Remove AC power to the

system for 10 seconds and

restart the system.
See "Troubleshooting

System Cooling

Problems" on page 180. If

the problem persists, see

"Getting Help" on

page 203.