4 ensure that all cables are properly connected, Troubleshooting the system battery, 4 enter the system setup program – Dell PowerEdge R910 User Manual

Page 178: See "troubleshooting the, System battery" on, Troubleshooting the

Advertising
background image

178

Troubleshooting Your System

• SD cards
• USB memory key
• NIC hardware key
• Expansion cards and both expansion-card risers
• I/O card
• Integrated storage controller
• Power supplies
• Processors and heat sinks

4 Ensure that all cables are properly connected.
5 Close the system. See "Closing the System" on page 90.
6 Run the system board tests in the system diagnostics. See "Running the

Embedded System Diagnostics" on page 194.
If the tests fail, see "Getting Help" on page 203.

Troubleshooting the System Battery

NOTE:

If the system is turned off for long periods of time (for weeks or months), the

NVRAM may lose its system configuration information. This situation is caused by a

defective battery.

1 Re-enter the time and date through the System Setup program. See "Using

the System Setup Program and UEFI Boot Manager" on page 63.

2 Turn off the system and disconnect it from the electrical outlet for at least

one hour.

3 Reconnect the system to the electrical outlet and turn on the system.
4 Enter the System Setup program.

If the date and time are not correct in the System Setup program, replace

the battery. See "Replacing the System Battery" on page 156.

NOTE:

Some software may cause the system time to speed up or slow down. If the

system seems to operate normally except for the time kept in the System Setup

program, the problem may be caused by software rather than by a defective

battery.

If the problem is not resolved by replacing the battery, see "Getting Help"

on page 203.