Dell PowerEdge R910 User Manual

Page 34

Advertising
background image

34

About Your System

E1812

Hard drive ##

removed.

Check drive.

The specified hard drive has

been removed from the

system.

Information only.

E1813

Internal Dual

SD Module

Card #

failed. Check

SD card.

The internal dual SD

module card has failed.

Reseat the internal dual

SD module card.
If the problem persists,

see "Getting Help" on

page 203.

E1814

Internal SD

Module Card #

write-

protected.

Check SD

card.

The internal dual SD

module card is write-

protected and cannot be

used.

Change the write-protect

switch setting on SD card.

E1815

Internal Dual

SD Module

redundancy

lost. Check

SD cards.

The internal dual SD

module bootable media is

no longer redundant.

Initiate a rebuild on the

next POST execution.
Reseat the internal dual

SD module card. See

"Removing an Internal SD

Card" on page 141 and

"Installing an Internal SD

Card" on page 141.
If the problem persists,

see "Getting Help" on

page 203.

E1A14

SAS cable A

failure.

Check

connection.

SAS cable A is missing or

bad.

Reseat the cable. If the

problem persists, replace

cable.
If the problem persists,

see "Getting Help" on

page 203.

Code

Text

Causes

Corrective Actions

book.book Page 34 Tuesday, December 4, 2012 3:11 PM

Advertising