Dell PowerEdge R910 User Manual

Page 58

Advertising
background image

58

About Your System

Warning: Control

Panel is not

installed.

The control panel is not

installed or has a faulty cable

connection.

Install the control panel, or

check the cable connections

between the display module,

the control panel board, and

the system board. See

"Control Panel Assembly" on

page 162.

Warning! No micro

code update

loaded for

processor

n.

Micro code update failed.

Update the BIOS firmware.

See "Getting Help" on

page 203.

Warning! Power

required exceeds

PSU wattage.

Check PSU and

system

configuration.

Warning!

Performance

degraded. CPU and

memory set to

minimum

frequencies to

meet PSU wattage.

System will

reboot.

The system configuration of

processor(s), memory

modules, and expansion

cards may not be supported

by the power supplies.

If any system components

were just upgraded, return

the system to the previous

configuration. If the system

boots without this warning,

then the replaced

component(s) are not

supported with this power

supply. If Energy Smart

power supplies are installed,

replace them with High

Output power supplies to use

the components. See "Power

Supplies" on page 153.

Warning! PSU

mismatch. PSU

redundancy lost.

Check PSU.

A High Output power supply

and an Energy Smart power

supply are installed in the

system at the same time.

Install two High Output or

two Energy Smart power

supplies in the system.
You can also run the system

on one power supply until

you can obtain two power

supplies of the same type.

See "Troubleshooting Power

Supplies" on page 179.

Message

Causes

Corrective Actions

book.book Page 58 Tuesday, December 4, 2012 3:11 PM