51 evc – Interlogix NS4702-24P-4S-4X Command Line Guide User Manual

Page 82

Advertising
background image

-82-

Default:

V2

Usage Guide:

To configure ERPS VLANs for the specific profile.

Example:

To configure ERPS VLANs(VLAN5 - VLAN8) for the specific profile 1.

Switch# configure terminal
Switch (config)# erps 1 vlan add 5-8

4.2.51 evc

Command:

evc <EvcId : 1-4096> vid <evc_vid> ivid <ivid> interface ( * | 10GigabitEthernet |

GigabitEthernet [ <port_list> ] ) learning [ disable ] policer { <PolicerId : 1-2048> |

none | discard }

<EvcId : 1-4096>

EVC identifier

vid

Setup EVC VLAN ID

<EvcVid : 1-4095>

EVC VLAN ID

ivid

Setup internal EVC VLAN ID

<Ivid : vlan_id>

Internal VLAN ID

interface

Setup NNI

learning

Setup learning

policer

Policer (ingress bandwidth profile)

<PolicerId : 1-2048>

Policer ID

<vlan_list>

List of VLANs

discard

Map to policer discarding all frames

none

Map to policer allowing all frames

Default:

0

Usage Guide:

To configure Ethernet Virtual Circuits (EVC).

Example:

To configure Ethernet Virtual Circuits (EVC identifier: 1, EVC VLAN ID: 2, GigabitEthernet Port: 1/1, 1/2, Internal

VLAN ID: 3, Disable learning, Policer ID: 4)

.

Switch# configure terminal

Advertising