Interlogix NS4702-24P-4S-4X Command Line Guide User Manual
Page 87

-87-
pcp
Setup added tag PCP
<AddPcp : 0-7>
Added tag PCP
preserve
Setup tag PCP/DEI preservation
type
Setup added tag type
c-tag
Add C-tag
none
No tag added
s-custom-tag
Add custom S-tag
s-tag
Add S-tag
vid
Setup added tag VLAN ID
<AddVid : vlan_id>
Added tag VLAN ID
match
Setup inner tag match properties
dei
Setup matched DEI
<MatchDei : 0-1>
Matched DEI
any
Match any DEI
pcp
Setup matched PCP
<MatchPcp : pcp>
Matched PCP value/range
any
Match any PCP
type
Setup matched tag type
any
Match tagged and untagged frames
c-tagged
Match C-tagged frames
s-tagged
Match S-tagged frames
tagged
Match tagged frames
untagged
Match untagged frames
vid
Setup matched VLAN ID
<Vid : 0-4095>
Matched VLAN ID value/range
any
Match any VLAN ID
interface
Setup UNI
next
Setup the ECE ID of the next entry
<EceId : 1-4096>
Select ECE ID of an existing entry
last
Make the ECE the last entry
outer-tag
Setup outer tag options
add Setup
outer tag add properties
dei Setup
added tag DEI
<AddDei : 0-1>
Added tag DEI
mode Setup
NNI-to-UNI outer tag add mode
disable No tag added when forwarding to UNI
enable Add tag when forwarding to UNI