Chapter 4: Testing and troubleshooting

100

Concord 4 Installation Manual

Codes

System event

333

System armed to AWAY

555

Phone/sensor test

888

System trouble condition

999

System in alarm

Table 16 below describes pager sensor/zone number and user number report
codes.

Table 16: Pager sensor/zone code and numbers

Code

Sensor/zone or user number

000

System event not caused by a zone or user

001

–096

Sensor/zone numbers 1 to 96

600

–829

Regular user codes 0 to 229 used

830-837

Partition master code used

838-845

Partition duress code used

846

System master code used

847

Installer code used

848

Dealer code used

850

Quick arm used

851

Keyswitch sensor used

852

System armed Itself (during service or power-up)

Outputs and sirens

You should test all outputs (onboard and SnapCard) to verify configuration
programming.

Note:

Be sure to contact the central monitoring station before activating outputs

that trigger from an alarm condition.

To test outputs:

1. Contact the central monitoring station to inform them you are testing the

system.

2. Verify that all wiring at the panel and output devices is correct.

3. Activate the appropriate device to trigger each output as programmed.