Chapter 3: Programming

66

Concord 4 Installation Manual

Siren options menu

Siren options - global settings

Immediate beeps

Shortcut: 0700

Default: Off

This setting determines whether the panel activates trouble beeps as
soon as a wireless device supervisory condition is detected (on), or if
the panel waits 10 hours after the supervisory condition is detected to
activate trouble beeps (off). (See “Timers -global settings” on page 57).

Disable trouble beeps

Shortcut: 0701

Default: Off

When you turn on this setting, the panel does not initiate beeps to alert
users of nonfire wireless device supervisory trouble and does not
protest on arming if the condition exists.

If Immediate beeps is on, trouble beeps sound for supervisory trouble
conditions regardless of this menu setting.

UL 98 options

Shortcut: 0702

Default: Off

This setting determines whether the panel complies with UL 98
requirements (4-hour trouble beep restart, 4-hour backup battery test, 4-
hour smoke (group 26) zone supervisory).

Global fire

Shortcut: 0703

Default: Off

This setting determines whether sirens in all partitions sound (on) if any
partition activates a fire alarm.

Silent panic

Shortcut: 0704

Default: Off

This setting determines whether touchpad police panic alarms are
audible (off) or silent (on).

Siren options - partition 1 setting

Siren verify

Shortcut: 0710

Default: Off

This setting determines whether the panel supervises the panel speaker
terminals (7 and 8). When this feature is on, the panel indicates a
trouble condition if no speaker is connected to panel speaker terminals.