Chapter 2: Installation

8

Concord 4 Installation Manual

Table 4 below describes the maximum wire length allowed between compatible
devices and the panel, and the minimum and maximum current draw of each
device.

Table 4: Wire length requirements

Device

Max. wire
length to
panel

Standby mA
draw

Alarm mA draw

SuperBus 2000 2x16 LCD alphanumeric
touchpad

22 ga.: 300 ft.
18 ga.: 750 ft.

15 mA

90 mA

SuperBus 2000 ATP 1000 alphanumeric
touchpad

22 ga.: 300 ft.
18 ga.: 750 ft.

12 mA

110 mA

SuperBus 2000 ATP 2100 alphanumeric
touchpad

22 ga.: 300 ft.
18 ga.: 750 ft.

30 mA

165 mA

SuperBus 2000 ATP 2600 alphanumeric
touchpad

22 ga.: 300 ft.
18 ga.: 750 ft.

30 mA

165 mA

SuperBus 2000 fixed display touchpad

22 ga.: 300 ft.
18 ga.: 700 ft.

11 mA

65 mA

SuperBus 2000 FTP 1000 fixed display
touchpad

22 ga.: 300 ft.
18 ga.: 700 ft.

12 mA

75 mA

SuperBus 2000 RF transceiver

22 ga.: 1,000
ft.
18 ga.: 2,500
ft.

45 mA

55 mA

SuperBus 2000 phone interface/voice module 22 ga.: 40 ft.

18 ga.: 120 ft.

25 mA

600 mA

SuperBus 2000 voice-only module

22 ga.: 40 ft.
18 ga.: 120 ft.

20 mA

300 mA (jumper)

600 mA (no
jumper)

SuperBus 2000 2 amp power supply

No load

No load

4 input/2 output SnapCard

N/A

20 mA

185 mA*

8Z hardwired zone expander SnapCard

N/A

38 mA

230 mA*

4 output SnapCard

N/A

1 mA

130 mA*

SuperBus 2000 8Z input module

22 ga.: 1,800
ft.
18 ga.: 4,000
ft.

18 mA

35 mA

SuperBus 2000 4-relay output module

22 ga.: 350 ft.
18 ga.: 900 ft.

12 mA

180 mA