Chapter 3: Programming

Concord 4 Installation Manual

49

Security - partition 1 to 6 settings

Account number

Shortcut: 0010 to 0060

Default: 00000

The account number is used as panel (or customer) identification for the
central monitoring station. The panel sends the account number every
time it reports to the central station. Account numbers must be 1 to 10
characters long.

Alpha characters A to F can be assigned to the account number by
pressing and holding buttons 1 to 6 respectively, until the character
appears.

When using the CID reporting format, the letter A is reported as a 0.

Quick arm

Shortcut: 0011 to 0061

Default: Off

This feature allows system arming without using an access code. When
quick arm is on, the system arming level can be increased from off to
stay, from off to away, or from stay to away, without entering an access
code. A valid access code is still required to decrease the arming level
or disarm the system.

Quick exit

Shortcut: 0012 to 0062

Default: On

This feature determines whether or not users can open and close a
standard entry/exit door without causing an alarm (while the system is
armed). This feature also allows you to leave the armed premises
without having to disarm and rearm the system. When this feature is on,
pressing D

on a touchpad (while the system is armed) starts a two-

minute timer that allows one standard entry/exit door (sensor groups 10
and 19 only) to be activated once (opened, then closed). When this
feature is off, you must disarm the system before any protected door is
opened.

Exit extension

Shortcut: 0013 to 0063

Default: On

This feature determines whether you can reenter and exit again through
an entry or exit delay door (without disarming and rearming the system).
This helps prevent exit faults and false alarms by allowing you to reenter
the premises for a forgotten item.

When this feature is on, the panel restarts the exit delay timer if you
reenter the premises through a standard delay door before the standard
exit delay time expires. When this feature is off, the exit delay timer
does not restart if you reenter the premises, forcing you to disarm the
system to avoid setting off an accidental alarm.

Keyswitch sensor

Shortcut: 0014 to 0064

Default: None

This feature lets you arm and disarm the system using either a
keyswitch wired to a hardwired zone input or a wireless door/window
sensor (sensor 01 to 96).

Note:

We recommend you program (learn) keyswitch sensors into

group 28.

For example, if sensor 1 is designated as the keyswitch sensor and the
system is disarmed, then tripping sensor 1 could arm the system to
Away. If the system is armed to Stay or Away, then tripping the sensor
could disarm the system (depending on keyswitch style).

The panel reports opening, closing, and force-armed reports (if turned
on) to the central monitoring station.