Chapter 4: Testing and troubleshooting

102

Concord 4 Installation Manual

To test the energy saver module:

1. Press *, * to display the system status, ENERGY SAVER OFF, and the present

TEMPERATURE nn°. The temperature displayed (and/or announced) should
match the house thermostat. If the temperatures do not match, refer to
“Accessory modules - bus device settings” on page 73.

Note:

There is a 5-minute delay after the energy saver module returns control

to the furnace/AC before it will override the furnace/AC again.

2. Press 7, 2

to turn on the ESM. The display shows ENERGY SAVER ON and

the ESM relay will click once.

3. Press 7, 2

again to turn the ESM off. The display shows ENERGY SAVER

OFF.

Fixed display LCD touchpad chime and trouble beep
tones

You can adjust the frequency (pitch) of chime and trouble beep tones from a
fixed display touchpad to a more desirable or distinct tone, or to compensate for
hearing impaired persons.

To change status tone pitch:

1. Press and hold the *

and 0

buttons together until you hear a steady tone, then

release the buttons.

Note:

Chime and trouble beep tones sound using the default frequency

during, or within 15 seconds of, any button activity at that specific touchpad.

2. Press and hold 1

to lower the pitch or press and hold 2

to raise the pitch.

3. Release the button when the desired pitch is heard.

After about 15 seconds of no touchpad activity, the steady tone stops
sounding.

Touchpad display contrast

You can adjust touchpad displays for easier viewing to help compensate for
lighting conditions in the touchpad location. The contrast adjustment lightens or
darkens the text. (Vacuum fluorescent displays do not have a contrast
adjustment.)

To adjust display contrast:

1. Enter configuration mode by pressing the D

and 6

buttons together for at least

2 seconds. The display shows DA nnn.