Interlogix Concord 4 REV J Installation Manual User Manual

Page 58

Advertising
background image

Chapter 3: Programming

52

Concord 4 Installation Manual

Backup

Shortcut: 01005,
01015, and 01025

Default: On (1),
Off (2 and 3)

This setting determines whether the panel uses another programmed
central station phone number for reporting if attempts with the first
number are unsuccessful.

When backup is off, the panel makes up to eight attempts to deliver a
report with the programmed phone number. When backup is set to on,
the panel makes up to 16 attempts to deliver the report, alternating
between the programmed phone number and the backup phone
number. Central station phone 1 is backed up by central station phone
2. Central station phones 2 and 3 are backed up by central station
phone 1.

SIA/CID reporting

Shortcut: 01006,
01016, and 01026

Default: CID

This setting determines whether the panel uses the SIA (press 1) or CID
(press 2) reporting format for central station communication.

Cellular backup

Shortcut: 01007,
01017, and 01027

Default: On (1),
Off (2 and 3)

This setting determines whether the panel uses cellular communication
for reporting if attempts using a landline are unsuccessful.

Phones - pager phone 1 to 5 settings

Cellular backup

Shortcut: 01030,
01040, 01050, 01060,
and 01070

Default: None

This feature programs a phone number that communicates to a pager.
Phone numbers can be 1 to 24 digits long and include pauses, a sky link
number, and 7-digit PIN code.

Call-waiting services should be disabled to prevent interrupting panel
communication to the pagers. To program a dialing prefix that disables
call waiting, see the call wait cancel setting under the “Phone options -
global settings

” on page 54.

To delete a pager phone number, with the display showing

PHONE

NUMBER

(current number), press D. The display shows

PHONE

NUMBER

_.

High level reports

Shortcut: 01031,
01041, 01051, 01061,
and 01071

Default: On

This setting determines whether the following alarm conditions report to
a pager:

• Fire, police, auxiliary, and duress alarms
• No activity
• Receiver failure (or jam)
• Tamper conditions, including zone tampers and system tamper (40
incorrect key presses or touchpad supervisory)
• Entering or exiting sensor test mode
• Phone test

Advertising