Chapter 2: Installation

Concord 4 Installation Manual

9

Device

Max. wire
length to
panel

Standby mA
draw

Alarm mA draw

SuperBus 2000 energy saver module

22 ga.: 1,600
ft.
18 ga.: 4,000
ft.

20 mA

20 mA

SuperBus 2000 automation module

22 ga.: 1,500
ft.
18 ga.: 4,000
ft.

30 mA

35 mA

SuperBus 2000 wireless cellular gateway

22 ga.: 40 ft.
18 ga.: 90 ft.

65 mA

1600 mA

Interrogator 200

22 ga.: 3,200
ft.
18 ga.: 4,500
ft.

10 mA

10 mA

Interrogator AVM

22 ga.: 110 ft.
18 ga.: 260 ft.

45 mA

300 mA

Two-wire smoke detectors (ESL 429AT,
429C, 429CT, 521B, 521BXT, 521NCSXT

22 ga.: 330 ft.
18 ga.: 330 ft.

70 µA

60 mA

Two-wire smoke detectors (system sensor
2400, 2400TH)

22 ga.: 330 ft.
18 ga.: 330 ft.

120 µA

80 mA

Hardwired interior siren (13-949)

22 ga.: 750 ft.
18 ga.: 1,500
ft.

0 mA

85 mA

Piezo dynamic exterior siren (13-950)

22 ga.: 750 ft.
18 ga.: 1,500
ft.

0 mA

150 mA

Speaker siren (60-528 or 13-060)

18 ga.: 100 ft. 0 mA

500 mA

*Maximum current draw for the SnapCards does not include the load which may be applied to
their auxiliary DC supply.

Table 5 below describes the total system wire lengths allowed for all SuperBus
2000 devices when installing systems using unshielded or shielded cable. After
determining panel location, run all necessary wires to that location using the
information in Table 6 on page 10.

Table 5: Wire lengths

Wire type

Total system wire

18-gauge, unshielded
18-gauge, shielded

4,000 ft.
3,000 ft.