Chapter 3: Programming

42

Concord 4 Installation Manual

Reporting

Global

24-hour tamper (06000) [Off]
Antenna tamper (06001) [Off]
Buffer control (06002) [Off]
Back in service (06003) [On]
Bypass reports (06004) [Off]
Low CPU battery (06005) [On]
Battery restoral (06006) [Off]
Buffer full report (06007) [Off]
Zone restorals (06008) [Off]
Two trip error (06009) [Off]
TP panic rpt fmt (06010) [Off]
AC failure (06011) [Off]
Receiver failure (06012) [Off]
RF low bat rpt (06013) [Weekly]
RF supv rpt (06014) [Weekly]
Swinger limit (06015) [1]
Ground fault (06017) [On]
Aux power fail (06016) [On]

Partition

Opening reports (06100 to 06600) [Off]
Closing reports (06101 to 06601) [Off]
No activity (06102 to 06602) [Off]
Duress option (06103 to 06603) [Off]
Force armed (06104 to 06604) [Off]
Latchkey format (06105 to 06605) [Off]
Freeze alarm (06106 to 06606) [Off]
Freeze temp (06107 to 06607) [42]
Alarm verify (06108 to 06608) [Off]
System tamper (06109 to 06609) [Off]
Report confirm (06111 to 06611) [Off]

Siren options

Global

Immediate beeps (0700) [Off]
Disable trbl beeps (0701) [Off]
UL 98 options (0702) [Off]
Global fire (0703) [Off]
Silent panic (0704) [Off]

Partition

Siren verify (0710 partition 1 only) [Off]

Sensors

Learn sensors (080)

Sensor partition 1 2 3 4 5 6
Sensor group [0]
Trip sensor n

Sensor text (081)

Text for sensor n
Sensor n item 0

Delete sensors (082)

Delete sensor n
Delete sensor n done

Edit sensors (083)

Sn P1 Gnn NC/NO/TP/RF/HW
Sensor partition n
Sensor group n

Audio
verification

Partition 1

Audio verify (09000) [Off]
Audio mode (09001) [1]
Fire shutdown (09002) [Off]
Silent talkback (09001) [Off]
Access timeout (09004) [90
seconds]
Beep delay (09005) [2 seconds]
Access code (09006) [****]
VOX mic gain (09007) [14]
VOX gain range (09008) [64]
Manual mic gain (09009) [04]
VOX RX gain (09010) [08]