Chapter 3: Programming

Concord 4 Installation Manual

57

Timers menu

Timers -global settings

Supervisory time

Shortcut: 0300

Default: set randomly
between 01:00 and
4:00.

This setting determines what time of day the panel sends supervisory,
low battery, or automatic phone test reports to the central station. Enter
the 4-digit time value (HH:MM). For example, enter 0330 to set the
supervisory time for 3:30 a.m.

The panel clock must be set with the correct time for accurate
supervisory t

ime reporting. See “

Time and date menu

” on page 83.

RF Tx timeout

Shortcut: 0302

Default: 12 hours

This setting determines how many hours (2 to 24) the panel has to
receive at least one signal from a wireless sensor (learned into a
supervised group). If the panel does not receive a signal from any
supervised wireless sensor within the set time, the panel reports a
supervisory condition to the central station.

Phone test frequency

Shortcut: 0303

Default: 7 days

This setting determines how often (1 to 255 days) the panel conducts
the automatic phone test (see “Phone options - global settings” on page
54).

Next phone test

Shortcut: 0304

Default: 7 days

This setting is used by the automatic phone test feature under “Phone
options - global settings

” on page 54 to determine when the next

automatic phone test should occur (1 to 255 days). This setting should
be the same as, or less than, the phone test frequency setting.

Output trip time

Shortcut: 0305

Default: 4 seconds

This setting determines how long outputs are activated when tripped (1
to 12 seconds), if they are configured for a momentary response.

Activity timeout

Shortcut: 0306

Default: 24 hours

This setting determines when the system sends a no activity report (1 to
42 hours). If no user interaction or device activation occurs in that time,
the panel sends a report to the central station.

Daylight saving

Shortcut: 0307

Default: On

When this setting is on, the panel clock automatically adjusts for daylight
saving time changes.