Chapter 3: Programming

Concord 4 Installation Manual

61

Reporting menu

Reporting - global settings

24-hour tamper

Shortcut: 06000

Default: Off

When this setting is turned on, the panel sounds sirens and reports a
tamper alarm (even when the system is disarmed), when nonfire
wireless sensor tamper switches are activated.

When this setting is turned off, the panel sounds sirens and reports a
tamper alarm only when nonfire wireless sensor tamper switches are
activated and those sensors are active for the current arming level.
For nonfire sensors not active in the current arming level that have
their tamper switch activated, trouble beeps sound and the panel
sends a sensor tamper report to the central station if the system
tamper feature is on for that partition.

Tamper conditions for fire sensors (group 26) always cause trouble
beeps to sound and report the tamper condition to the central station,
regardless of this feature setting.

Antenna tamper

Shortcut: 06001

Default: Off

This setting determines whether the panel monitors for antenna
tamper of onboard and all connected bus transceivers and receivers.
When turned on, the panel sounds trouble beeps in all partitions and
reports an antenna tamper condition. Touchpads in all partitions show
a receiver tamper trouble condition. When turned off, the panel
ignores antenna tampers.

Buffer control

Shortcut: 06002

Default: Off

When this setting is on, only arming level changes and time changes
(system time and daylight saving time) are logged in the buffer
(memory) of the panel. When this setting is off, all system events are
logged in the buffer.

Back in service

Shortcut: 06003

Default: On

When this setting is on, the panel reports to the central station when
AC and backup battery power are restored (after an extended power
outage).

Bypass reports

Shortcut: 06004

Default: Off

When this setting is on, the panel reports to the central station
whenever sensors or zones are bypassed.

Low CPU battery

Shortcut: 06005

Default: On

When this setting is on, the panel reports a low panel battery to the
central station when the system battery test fails. If this setting and the
Aux power fail feature are both on, the panel also monitors for and
reports a low battery for the SuperBus 2000 2-amp power supply.

Battery restoral

Shortcut: 06006

Default: Off

If this setting is on, the panel reports to the central monitoring station
when a wireless sensor or touchpad reports a battery replacement to
the panel.

Buffer full report

When this setting is on, the panel sends an event buffer full report to
the central monitoring station when the event buffer is nearing full.