Chapter 2: Installation

Concord 4 Installation Manual

21

Interrogator 200 audio verification module

A maximum of two audio veification modules (AVM) are allowed (partition 1 only).
Connect the Interrogator 200 AVM to the panel terminals as shown in Figure 13
below. Use shielded cable to prevent crosstalk between the speaker and
microphone.

Figure 13: Connecting an Interrogator 200

Panel terminals

SPKR

SPKR

+12V MIC GND

Yellow

Splice

Audio verification
module

Caution:

If a speaker is already connected to panel terminals 7 and 8, the

Interrogator 200 speaker must be hooked up in series with that speaker to
provide a 16-ohm load. Hooking up speakers in parallel to panel terminals 7 and
8 creates a 4-ohm load that can cause permanent damage to the panel.