Appendix B: Reference tables

Concord 4 Installation Manual

143

Response characteristics

Table 30 below describes the response characteristics.

Table 30: Response characteristics

Response characteristics

Description

Momentary trip time

The point remains active for nn seconds (n is 1 to 12 seconds).
The default is 4 seconds.

3-minute trip time

The point remains active for 3 minutes.

Siren-time trip time

The point remains active while the sirens are sounding.

Sustained trip time

The point remains active for the duration of the event.

Siren pattern

The point activates and deactivates according to the current
alarm type:

Auxiliary: fast on/off/on

Police: constant on

Fire: repeating

Trip delay

The point activates 30 seconds after the trigger event occurs.

Response numbers

Table 31 below describes the response numbers.

Table 31: Response numbers

Response number

Siren tracking

Trip delay

Response time

00

No

No

Momentary

01

No

No

3 minutes [5]

02

No

No

Siren time [2]

03

No

No

Sustained [3]

04

No

Yes [4]

Momentary

05

No

Yes [4]

3 minutes [5]

06

No

Yes [4]

Siren time [2]

07

No

Yes [4]

Sustained [3]

08

Yes [1]

No

Momentary

09

Yes [1]

No

3 minutes [5]

10

Yes [1]

No

Siren time [2]