Chapter 3: Programming

Concord 4 Installation Manual

55

that time.

Communication
failure

Shortcut: 02003

Default: On

This setting determines whether the panel activates trouble beeps to
alert users on the premises that communication to the central station
failed. Failure notification occurs after the third unsuccessful reporting
attempt to the central station/pager.

Failure notification can occur immediately if inadequate phone line
voltage is detected upon the initial dialing attempt.

DTMF dialing

Shortcut: 02004

Default: On

This setting determines whether the panel uses DTMF tones (on) or
pulse (off) for dialing programmed phone numbers.

Dialer abort delay

Shortcut: 02006

Default: 30 seconds

This setting determines how much time the user has to abort a panel
alarm report (15 to 45 seconds).

Cancel message

Shortcut: 02007

Default: On

This setting determines whether the panel displays a cancel message
after the user disarms the system to clear an alarm condition.

Pager delay

Shortcut: 02008

Default: 15 seconds

This setting determines how long a report is delayed to a pager (0 to
30 seconds), after the panel dials the pager number.

The pager delay time should not be set below 5 seconds, unless
necessary.

Call wait cancel

Shortcut: 02009

Default: None

This feature sets up a dialing prefix to disable the call waiting feature
before the panel makes its first dialing attempt to any programmed
central monitoring station or downloader phone number. The prefix
can be up to eight digits.

Note:

We recommend that you program two pauses in any call wait

cancel dialing prefix to ensure proper operation.

To delete the call wait cancel prefix, with the display showing

CALL

WAIT CANCEL

(or current setting), press D.

Caution:

Do not change this option from its default until verifying with

the customer that he has call waiting with his phone service provider.
Changing this option from its default without call waiting will prohibit
the panel from calling the central station.

Dial tone detect

Shortcut: 02010

Default: On

When this setting is on, the panel begins dialing as soon as it detects
a dial tone. When this feature is off, the panel begins dialing a few
seconds after seizing the phone line. There is no dial tone detect on
the last dialing attempt.