Example 3 (Pr. 5-07 = d3) Execute one cycle step by step:

The example shows how the PLC can perform one cycle at a time, within a complete cycle. Each

step will use the acceleration/deceleration times in Pr.1-09 to Pr.1-12. It should be noticed that the

time each step spends at its intended frequency is diminished, due to the time spent during

acceleration/deceleration.

Frequency

60Hz

50Hz

40Hz

30Hz

20Hz

15Hz

10Hz

0Hz

5-13

5-14

5-15

5-16

5-03

5-04

5-05

5-06

Program step
complete

Program operation
completed

t

t

t

t

5Hz

5-09

Master freq.=5Hz
5-00=10 Hz
5-01=20 Hz
5-02=40 Hz
5-03=60 Hz
5-04=50 Hz
5-05=30 Hz
5-06=15 Hz

4-07=d17
3-05=d11
3-06=d12
5-07=d3
5-08=d0

5-09=10
5-10=10
5-11=12
5-12

Sec
Sec

Sec

=15 Sec

5-13=15 Sec
5-14=8 Sec
5-15=17 Sec
5-16=17 Sec

Time
(Sec)

Example 4 (Pr. 5-07 =d4) Continuously execute PLC cycles step by step:

In this explanation, the PLC program runs continuously step by step. Also shown are examples of

steps in the Reverse direction.

Frequency

60Hz

50Hz

40Hz

30Hz

20Hz

15Hz

10Hz

0Hz

Time
(Sec)

FWD

REV

t

5-09

Master freq.=5Hz
5-00=10 Hz
5-01=20 Hz
5-02=40 Hz
5-03=60 Hz
5-04=50 Hz
5-05=30 Hz
5-06=15 Hz

4-07=d17
3-05=d10
3-06=d11
5-07=d4
5-08=d68

5-09=10
5-10=10
5-11=12
5-12

Sec
Sec

Sec

=15 Sec

5-13=15 Sec
5-14=8 Sec
5-15=17 Sec
5-16=17 Sec