background image

Chapter 5 Parameters|VFD-S Series

Revision August 2006, SE08, SW V2.61

5-65

Start
bit

0

1

2

3

4

5

6

Stop
bit

Stop
bit

8-bit character

11-bit character frame

( 8.N.2 )

Start
bit

0

1

2

3

4

5

6

Even

parity

Stop
bit

11-bit character frame

( 8.E .1 )

Start
bit

0

1

2

3

4

5

6

Stop
bit

11-bit character frame

( 8.O.1 )

Odd

parity

7

7

7

8-bit character

8-bit character

3. Communication Protocol

3.1 Communication Data Frame:

ASCII mode:

STX

Start character ‘:’ (3AH)

ADR 1
ADR 0

Communication address:
8-bit address consists of 2 ASCII codes

CMD1
CMD0

Command code:
8-bit command consists of 2 ASCII codes

DATA (n-1)

…….

DATA 0

Contents of data:
n x 8-bit data consist of 2n ASCII codes.

n <= 25

,maximum of 50 ASCII codes

LRC CHK 1
LRC CHK 0

LRC check sum:
8-bit check sum consists of 2 ASCII codes

END1
END0

End characters:
END1= CR (0DH), END0= LF (0AH)

RTU mode:

START

A silent interval of more than 10 ms

ADR

Communication address: 8-bit address

CMD

Command code: 8-bit command

DATA (n-1)

…….

DATA 0

Contents of data:
n x 8-bit data, n<= 25

CRC CHK

Low

CRC CHK

High

CRC check sum:
16-bit check sum consists of 2 8-bit characters

END

A silent interval of more than 10 ms

Advertising