Delta Electronics AC Motor Drive VFD007S23A User Manual

Page 122

Advertising
background image

Chapter 5 Parameters|VFD-S Series

Revision August 2006, SE08, SW V2.61

5-67

RTU mode:

Command message:

Response message:

ADR 01H

ADR 01H

CMD 03H

CMD 03H

21H

Starting data

address

02H

Number of data

(count by byte)

04H

00H

17H

Number of data
(count by word)

02H

Content of address

2102H

70H

CRC CHK Low

6FH

00H

CRC CHK High

F7H

Content of address

2103H

00H

CRC CHK Low

FEH

CRC CHK High

5CH

(2) 06H: single write, write single data to register.

Example: writing data 6000(1770H) to register 0100H. AMD address is 01H.

ASCII mode:

Command message:

Response message:

STX ‘:’

STX ‘:’

‘0’

‘0’

ADR 1
ADR 0

‘1’

ADR 1
ADR 0

‘1’

‘0’

‘0’

CMD 1
CMD 0

‘6’

CMD 1
CMD 0

‘6’

‘0’

‘0’

‘1’

‘1’

‘0’

‘0’

Data address

‘0’

Data address

‘0’

‘1’

‘1’

‘7’

‘7’

‘7’

‘7’

Data content

‘0’

Data content

‘0’

‘7’

‘7’

LRC CHK 1
LRC CHK 0

‘1’

LRC CHK 1
LRC CHK 0

‘1’

CR

CR

END 1
END 0

LF

END 1
END 0

LF

RTU mode:

Command message:

Response

message:

ADR 01H

ADR 01H

CMD 06H

CMD 06H

01H

01H

Data address

00H

Data address

00H

17H

17H

Data content

70H

Data content

70H

CRC CHK Low

86H

CRC CHK Low

86H

CRC CHK High

22H

CRC CHK High

22H

(3) Command code: 10H, write n word, n<=12

For example, writing 6000(1770H) to Pr 5-00 (address 0500H) and1000(03E8H) to Pr 5-01

(address 0501H) with slave address 01H.

Advertising