Chapter 5 Parameters|VFD-S Series

5-38

Revision August 2006, SE08, SW V2.61

Hz

0V

4mA

10V
20mA

30

0

60

Potentiometer Scale

Max.
Output
Freq.

60Hz

Pr.1-00

0Hz

0V
4mA

10V
20mA

Factory Settings

Pr.1-00=60Hz--Max. output Freq.
Pr.4-00=60Hz--Potentiometer bias freq.
Pr.4-01=1 -- bias polarity
Pr.4-02=100% -- pot. freq. gain
Pr.4-03=1 -- pot. REV. motion enable

anti-slope

4-04

Multi-function Input Terminal (M0, M1)

Settings

d0 to d29

Factory Setting: d1

4-05

Multi-function Input Terminal (M2)

Factory Setting: d6

4-06

Multi-function Input Terminal (M3)

Factory Setting: d7

4-07

Multi-function Input Terminal (M4)

Factory Setting: d8

4-08

Multi-function Input Terminal (M5)

Factory Setting: d9

Parameters & Functions table:

Value

Function

Value

Function

d0

No Function

d15 Up: Increment master frequency

d1

M0: FWD / STOP, M1: REV / STOP

d16 Down: Decrement master frequency

d2

M0: RUN / STOP, M1: FWD / REV

d17 Run PLC Program

d3

3-Wire Operation Control mode (M0,
M1, M2)

d18 Pause PLC Program

d4

External Fault (Normally Open)

d19 Counter Trigger Signal

d5

External Fault (Normally Closed)

d20 Counter Reset

d6 External

Reset

d21

Select ACI / Deselect AVI (the priority is
higher than Pr. 2-00 and d26)

d7

Multi-Step Speed Command1

d22 PID function disable

d8

Multi-Step Speed Command2

d23 JOG FWD

d9

Multi-Step Speed Command3

d24 JOG REV

d10 Jog

operation

d25

The source of master frequency is AVI. (The
priority is higher than Pr. 2-00 and d26)

d11

Acceleration/Deceleration Speed
Inhibit

d26

The source of master frequency is ACI. (The
priority is higher than Pr. 2-00)

d12

First or Second Acceleration or
Deceleration Time Selection

d27

Press UP/DOWN

key to switch

forward/reverse (N.O.) motion

d13

External Base Block (N.O.)
(Normally Open Contact Input)

d28

Press UP/DOWN

key to switch

forward/reverse (N.C.) motion

d14

External Base Block (N.C.)
(Normally Close Contact Input)

d29

M0: 0: RUN 1: STOP, M1: no function,
Direction is controlled by keypad