Delta Electronics AC Motor Drive VFD007S23A User Manual

Page 110

Advertising
background image

Chapter 5 Parameters|VFD-S Series

Revision August 2006, SE08, SW V2.61

5-55

1

2

3

4

5

60Hz or more

50Hz

10Hz

5Hz

0

20 40

60

80 100 120 140 160 180 200

Operation
time(min)

Load
factor (%)

6-08

Present Fault Record

6-09

Second Most Recent Fault Record

6-10

Third Most Recent Fault Record

Factory Setting: d0

Readings

d0

No

fault

d1

Over-current

(oc)

d2

Over-voltage

(ov)

d3

Overheat

(oH)

d4

Overload

(oL)

d5

Overload1

(oL1)

d6

External fault (EF)

d7

Reserved

d8

Reserved

d9

Current exceeds 2 times rated current during accel. (ocA)

d10

Current exceeds 2 times rated current during decel.(ocd)

d11

Current exceeds 2 times rated current during steady state operation
(ocn)

d12

Ground fault (GF)

d13

Reserved

d14

Low voltage (Lv)

d15

CPU failure 1 (cF1)

d16

CPU failure 2 (cF2)

d17

Base block (b.b.)

d18

Overload

(oL2)

d19

Auto acceleration/deceleration failure (cFA)

Advertising