Correct wiring

M1

M2

Mn

reactor

AC motor drive

AC motor drive

AC motor drive

motor

motor

motor

Application 2

Question

Silicon rectifier and AC motor drive are
connected to the same power.

Switching spikes will be generated when the
silicon rectifier switches on/off. These spikes
may damage the mains circuit.

Correct wiring

DC

power

reactor

reactor

AC motor drive

motor

silicon rectifier