Chapter 5 Parameters|VFD-S Series

5-4

Revision August 2006, SE08, SW V2.61

Pr. Explanation

Settings

Factory

Setting

NOTE

2-00

Source of Master Frequency
Command

d4: Master Frequency operated by

RS-485 serial communication
interface and record frequency
of power loss. (record the
frequency of power loss and it
can do analog overlap plus)

d5: Master Frequency operated by

RS-485 serial communication
interface and won’t record
frequency before power loss.
(won’t record the frequency of
power loss and it can do analog
overlap plus)

d0

2-01

Source of Operation
Command

d0: Digital Keypad
d1: External terminals. Keypad

STOP/RESET enabled.

d2: External terminals. Keypad

STOP/RESET disabled.

d3: RS-485 serial communication

(RJ-11) .Keypad STOP/RESET
enabled.

d4: RS-485 serial communication

(RJ-11). Keypad STOP/RESET
disabled.

d0

2-02 Stop

Method

d0: STOP: ramp to stop; E.F.: coast

to stop

d1: STOP: coast to stop; E.F.: coast

to stop

d0

2-03

PWM Carrier Frequency Selections

d3: 3KHz
d4: 4KHz
d5: 5KHz
d6: 6KHz
d7: 7KHz
d8: 8KHz
d9: 9KHz
d10: 10KHz

d10

2-04

Motor Direction Control

d0: Enable forward/reverse

operation

d1: Disable reverse operation

d0

2-05

Loss of ACI Signal

d0: Decelerate to 0 Hz
d1: Coast to stop and display “EF”
d2: Continue operation by last

frequency command

d0

2-06

Analog Auxiliary Frequency Operation

d0: Disable
d1: Enable + AVI
d2: Enable + ACI

d0

Group 3 Output Function Parameters

Advertising