Delta Electronics AC Motor Drive VFD007S23A User Manual

Page 152

Advertising
background image

Chapter 8 Maintenance and Inspections|VFD-S Series

Revision August 2006, SE08, SW V2.61

8-5

Printed circuit board and connector of main circuit

Maintenance

Period

Check Items

Methods and Criterion

Daily

Half

Year

One

Year

If there are any loose screws and
connectors

Tighten the screws and press the
connectors firmly in place.

If there is any peculiar smell and
color change

Visual inspection and smell

If there is any crack, damage,
deformation or corrosion

Visual inspection

If there is any leaked liquid or
deformation in capacitors

Visual inspection

Cooling fan of cooling system

Maintenance

Period

Check Items

Methods and Criterion

Daily

Half

Year

One

Year

If there is any abnormal sound or
vibration

Visual, aural inspection and turn the
fan with hand (turn off the power
before operation) to see if it rotates
smoothly

If there is any loose screw

Tighten the screw

If there is any change of color due
to overheating

Change fan

Ventilation channel of cooling system

Maintenance

Period

Check Items

Methods and Criterion

Daily

Half

Year

One

Year

If there is any obstruction in the
heat sink, air intake or air outlet

Visual inspection

Advertising