PROGRAMMABLE_POWER_MAXIMUM_HIGH_SPEED_FRACTION_OF_USED_LAB_TI

LES

Sets an upper limit on the fraction of the LAB tiles used by your design that can be high-speed. Legal

values must be between 0.0 and 1.0. The default value is 1.0. A value of 1.0 means that there is no

restriction on the number of high-speed tiles, and the fitter will use the minimum number needed to meet

the timing requirements of your design. Specifying a value lower than 1.0 might degrade timing quality,

because some timing critical resources might be forced into low-power mode.

Type

String

Device Support

This setting can be used in projects targeting any Altera device family.

Notes

This assignment is included in the Fitter report.

Syntax

set_global_assignment -name PROGRAM-
MABLE_POWER_MAXIMUM_HIGH_SPEED_FRACTION_OF_USED_LAB_TILES <value>

Default Value

1.0