Fronius Energy Package User Manual

Page 103

Advertising
background image

101

EN

The ripple control signal receiver and the Fronius system monitoring connector are con-
nected to one another by means of a four-pin cable in accordance with the connection di-
agram.
If the distance between the Fronius system monitoring datalogger and the ripple control
signal receiver exceeds 10 m, a shielded cable is recommended.

EVU Editor settings:

EVU Editor – Dy-
namic power re-
duction

Utility companies or grid operators may stipulate feed-in limitations for an inverter (e.g.
max. 70% of kWp or max. 5 kW).
Dynamic power reduction takes account of self-consumption by the household before the
power of an inverter is reduced:
-

A custom limit can be set.

-

A Fronius Smart Meter can be connected to the D- / D+ connection sockets for Mod-
bus data on the system monitoring datalogger.

With the Fronius Symo Hybrid, any PV power that is not allowed to be fed into the grid is
used to charge the Fronius Solar Battery instead so that it does not go to waste. Dynamic
power reduction is only activated if the battery is full or cannot be charged for some other
reason.

60 %

30 %

0 %

0,95

0,90

0,85

(1)

(2)

(4)

+

-

IO 2

IO 3

I 4

I 7

I 8

I 9

IO 0

(3)

(1)

(2)