Fronius Energy Package User Manual

Page 35

Advertising
background image

33

EN

M_NO

Number of modules displayed

00 - 15

CYCL

Number of cycles

0000 - 9999

T

Average temperature of all cells

-99.9 °C to +99.9 °C

“Alarm bits” display

Indicator Details

Display

M_NO

Number of modules displayed

00 - 15

ALRM

Module status

8000 [Over Volt]: Overvoltage
4000 [Terminate]: End charging
2000 [Under Volt]: Undervoltage
1000 [Over Curr]: Overcurrent
0800 [Over Temp]: Overtemperature
0400 [0]:
0200 [Resistor]: Resistor alarm
0100 [Unbalance]: Cell imbalance
Details displayed if multiple alarms
are triggered
Example: If both “Over Current” and
“Over Temp” are detected, the follow-
ing message is displayed. A higher bit
level takes priority over messages in
brackets: “ALRM=1800 [Over Curr]”

“Heatsink Temp” display

Indicator Details

Display

HEAT-
SINK_T-
MP

Temperature of the heat sink

-40 °C to +119 °C