Settings – battery management – Fronius Energy Package User Manual

Page 96

Advertising
background image

94

Settings – Battery management

Battery manage-
ment

(2) battery charge from producers in the home network:
If further decentralised producers are installed in the household and have been integrated
into the self-consumption rule for the Fronius Symo Hybrid, you must activate this setting.
This means that energy can be drawn from the home network and fed into the Fronius So-
lar Battery for charging purposes via the Fronius Symo Hybrid.

You can restrict how much power is consumed by the Fronius Symo Hybrid by specifying
the maximum AC power. The maximum power consumption is limited to the AC nominal
output of the Fronius Symo Hybrid.

To ensure smooth operation in conjunction with other energy producers, it is important to
install the Fronius Smart Meter at the feed-in point. The Fronius Symo Hybrid and other
energy producers must be connected to the public grid via the Fronius Smart Meter.

(3) Calibration charge:
At regular intervals, the Fronius Symo Hybrid automatically charges the Fronius Solar Bat-
tery until it is full for the purpose of calibrating all the components. This process can be
started manually here.

Important! When calibration charging is activated, normal operation is interrupted and the
system may draw energy from the utility company grid. The process can take several hours
and cannot be aborted.

(1) reserve battery capacity:
This function is required to prevent available energy
from going to waste if the photovoltaic system is over-
dimensioned or in the case of dynamic power reduc-
tion. Up until a certain time of day, energy is only fed
into the Fronius Solar Battery if dynamic power re-
duction is active or if the amount of PV power availa-
ble on the Fronius Symo Hybrid exceeds what can be
delivered on the AC side (overdimensioning).

Consequently, storage space is “reserved” in the Fro-
nius Solar Battery to accommodate this operating
scenario. Standard energy management (self-con-
sumption optimisation) only resumes once the set
time is reached.

(1)

(2)

(3)

Advertising