*) If the status code is displayed all the time: Notify a Fronius-trained service engineer.

**) If this status code keeps recurring, contact your system engineer.

Class 10 - 12 sta-
tus codes

Customer service

Operation in
dusty environ-
ments

When operating the inverter in extremely dusty environments:
when necessary, clean the cooling elements and fan on the back of the inverter as well as
the air intakes at the wall bracket using clean compressed air.

985

Undervoltage at Fronius Solar
Battery

Fronius Solar Battery has
tripped due to undervoltage.
Battery operation not possi-
ble, feed-in resumes

*)

986

Overtemperature at Fronius
Solar Battery

Fronius Solar Battery has
tripped due to overtempera-
ture. Battery operation not
possible, feed-in resumes

Reduce ambient temperature;
switch off Fronius Solar Battery
and activate it again after waiting
an appropriate amount of time; *)

987

Undertemperature at Fronius
Solar Battery

Fronius Solar Battery has
tripped due to undertemper-
ature. Battery operation not
possible, feed-in resumes

Increase ambient temperature;
switch off Fronius Solar Battery
and activate it again after waiting
an appropriate amount of time; *)

988

Communication error between
Fronius Symo Hybrid and Fro-
nius Smart Meter

No meter data available
Battery operation not possi-
ble, feed-in resumes

Check wiring; **)

989

No communication between
Fronius Symo Hybrid and Fro-
nius Smart Meter

No meter data available
Battery operation not possi-
ble, feed-in resumes

Check wiring; check Fronius
Smart Meter power supply; **)

Code

Description

Behaviour

Remedy

1000 - 1299- Provide information on the status of the internal processor program
Description

Is of no concern when the inverter is working properly and only
appears in the "Status PS" setup parameter. In the event of an
actual error, this status code assists Fronius Technical Support
during the error analysis.

IMPORTANT! Contact your Fronius dealer or a Fronius-trained service technician if
-

an error appears frequently or all the time

-

an error appears that is not listed in the tables

Advertising