The INFO menu item

Measured values

PV ins.
Insulation resistance of the photovoltaic system and the storage system

Ext. lim.
External power reduction in per cent e.g. specified by grid operator

U PV
Current PV voltage on the terminals even if the inverter is feeding in no power whatsoever

GVDPR
Grid voltage-dependent power reduction

Fan #1
Percentage of target output for fan

PSS status

The status of the most recent inverter fault can be displayed.

IMPORTANT! Due to the low level of insolation early in the morning and in the evening,
the status codes 306 (Power low) and 307 (DC low) are displayed routinely at these times
of day. These status codes do not indicate any kind of fault.

-

Press the 'Enter' key to see the status of the power stage set and the most recent fault

-

Use the 'Up' and 'Down' keys to scroll through the list

-

Press the 'Back' key to close the status and fault list

Grid status

The five most recent grid faults can be displayed:
-

Press the 'Enter' key to see the five most recent grid faults

-

Use the 'Up' and 'Down' keys to scroll through the list

-

Press the 'Back' key to close the grid fault display

Device informa-
tion

For displaying the settings that will be of relevance to a utility company. The values shown
will depend on the country setup or the device-specific settings of the inverter.

Display area

General / Country-specific setting / MPP Tracker / Grid monitor-
ing / Grid voltage limits / Grid frequency limits / Q-mode / AC
power limit

General:

Device type
Fam.

Country-specific set-
ting:

Setup
Specified country setup

Version
Version of country setup

Group
Group for updating the inverter software

MPP Tracker:

PV Tracker