background image

121

EN

Technical data

Fronius Symo Hybrid

3.0-3-S

4.0-3-S

5.0-3-S

Input data
PV input power

5 kW

6.5 kW

8 kW

MPP voltage range

190 - 800 V DC

250 - 800 V DC

315 - 800 V DC

Max. input voltage
(at 1000 W/m²/ -10 °C in an open circuit)

1000 V DC

Feed-in start voltage

200 V

Nominal input voltage

595 V

Min. input voltage

150 V DC

Max. input current

1 x 16.0 A

Max. short circuit current of the solar mod-
ules (I

SC PV

)

24.0 A

Number of MPP trackers

1

Number of DC connections

2

Battery input
Max. output power to battery

Dependent on connected Fronius Solar Battery

Max. input power from battery

Dependent on connected Fronius Solar Battery

Output data
Nominal output power (P

nom

)

3000 W

4000 W

5000 W

Max. output power

3000 VA

4000 VA

5000 VA

Nominal grid voltage

3~ NPE 400/230 V3~ NPE 380/220 V (+20% / -30%)

Max. output current

4.5 A

6.0 A

7.6 A

Frequency (frequency range)

50 Hz / 60 Hz (45 - 65 Hz)

Total harmonic distortion

< 3%

cos phi power factor

0.85 - 1 ind./cap.

2)

Power-up current pulse

6)

and duration

38 A / 2 ms

Max. overcurrent protection

25 A

General data
Max. efficiency (PV - grid)

97.5%

97.6

Max. efficiency (PV - battery - grid)

> 90%

> 90%

> 90%

Europ. efficiency (PV - grid)

95.2%

95.7%

96%

Cooling

Controlled forced-air ventilation

Degree of protection

IP65

Dimensions h x w x d

645 x 431 x 204 mm

Weight

22 kg

Permissible ambient temperature

-25 °C - +60 °C

Permitted humidity

0 - 100%

EMC device class

B

Overvoltage category DC / AC

3 / 2

Pollution level

2

Noise emission

59.5 dB(A) ref. 1pW

Protection devices
DC insulation measurement

Integrated

Response to DC overload

Operating point shift, power limitation

Advertising