Fronius Energy Package User Manual

Page 34

Advertising
background image

32

CON

Status of connected modules

In the above example, there are 6
connected modules (no. 00 - no. 05).

“Status” display

Indicator Details

Display

M_NO

Number of modules displayed

00 - 15

STAT

Module status

YX (Y: Current status, X: Previous
status)
1X [Pre Charge]: Pre-charging
2X [Initial]: Status at beginning
3X [Normal Chg]: Normal charging
4X [Terminate]: End charging
5X [Normal Dis]: Normal discharging
6X [Over Volt]: Overvoltage
7X [Over Dis]: Deep discharge
8X
9X [Over Temp C]: Overtemperature
charging

AX [Over Curr C]: Overcurrent charg-
ing
BX [Over Temp D]: Overtemperature
discharging
CX [Over Curr D]: Overcurrent dis-
charging
DX [Unbalance]: Cell imbalance
EX [Chg Suspend]: Charging sus-
pended
FX

“Mode, Current, SOC, Voltage” display

Indicator Details

Display

M_NO

Number of modules displayed

00 - 15

RSOC

Remaining module capacity

0% - 100%

I

System module current strength

-999.9 A to +999.9 A

V

System module voltage

0.0 V to +999.9 V

“Cell Temp., Cycle Count” display

Indicator Details

Display