Hd4070 process sequence – continued – Hypertherm HD4070 Rev.8 User Manual

Page 157

Advertising
background image

MAINTENANCE

5-10

HD4070

Instruction Manual

1

HD4070 Process Sequence – continued

Continued from previous page

State 5 – Pilot Arc

• Gas console set to state 2 (ignitors ON).
• Waits for current.
• Pilot arc will timeout in 1 second if no current is detected.

State 6 – Transfer

• Waits for transfer signal.
• Gas console set to stage 3 (ignitors off).
• Transfer will time-out in 2 seconds.

(Default value) it can also be set for 0.3

State 7 – Ramp-up

• Gas console sets state 5 (steady state)

after pierce delay timer expires.

• Machine motion output ON.

State 8 – Steady State

• Steady state current maintained.
• Waits for cycle start to be removed.

State 9 – Ramp-down

• Rampdown gas and current.
• Gas console set to state 6 (rampdown).

State 10 – Final Ramp-down

• Choppers turn OFF.
• Gas console set to state 0 (all outputs OFF).

State 11 – Auto OFF

• Fan and contactor timers start.
• Start signal OFF.

Pilot Current Detected

Transfer Complete

Ramp-up Complete

Cycle Start Removed

Ramp-down Complete

Advertising