Error code troubleshooting- 4 of 4 -18, Error code troubleshooting (4 of 4) – Hypertherm HD4070 Rev.8 User Manual

Page 165

Advertising
background image

MAINTENANCE

5-18

HD4070

Instruction Manual

4

Error Code Troubleshooting (4 of 4)

ID #

Error Code or Message

Description

Corrective action

123

MV 1 ERROR

Motor valve #1 did not move when commanded.

(1) Check all cables from relay PCB to Motor valves. (2) Check LED for relay

PCB#1, Shown later in this section. (3) Check relay PCB#1 incoming signal.

(4) Check relay PCB#1 output signal. (5) Switch cables to a working MV; If

MV works, replace malfunctioning MV. If MV does not work, replace or repair

cables. (6) Broken wire or cable. P1-4, P12-2, P2-4, PL1 and P3-1 not

seated properly. Pin or socket not seated in plug housing properly. Faulty SSR

on relay board. Loss of signal from control board to relay board.

124

MV 2 ERROR

Motor valve #2 did not move when commanded.

(1) Check all cables from relay PCB to Motor valves. (2) Check LED for

relay PCB#1, Shown later in this section. (3) Check relay PCB#1 incoming

signal. (4) Check relay PCB#1 output signal. (5) Switch cables to a

working MV; If MV works, replace malfunctioning MV. If MV does not work,

replace or repair cables. (6) Broken wire or cable. P1-5, P12-2, P2-5, PL2

and P3-1 not seated properly. Pin or socket not seated in plug housing

properly. Faulty SSR on relay board. Loss of signal from control board to relay

board.

125

MV 3 ERROR

Motor valve #3 did not move when commanded.

(1) Check all cables from relay PCB to Motor valves. (2) Check LED for relay

PCB#2, Shown later in this section. (3) Check relay PCB#2 incoming signal.

(4) Check relay PCB#2 output signal. (5) Switch cables to a working MV; If

MV works, replace malfunctioning MV. If MV does not work, replace or repair

cables. (6) Broken wire or cable. P1-6, P12-2, P2-6, PL3 and P2-3 not

seated properly. Pin or socket not seated in plug housing properly. Faulty SSR

on relay board. Loss of signal from control board to relay board.

126

MV 4 ERROR

Motor valve #4 did not move when commanded.

(1) Check all cables from relay PCB to Motor valves. (2) Check LED for relay

PCB#2, Shown later in this section. (3) Check relay PCB#2 incoming signal.

(4) Check relay PCB#2 output signal. (5) Switch cables to a working MV; If

MV works, replace malfunctioning MV. If MV does not work, replace or repair

cables. (6) Broken wire or cable. P1-7, P12-2, P2-7, PL4 and P2-3 not

seated properly. Pin or socket not seated in plug housing properly. Faulty SSR

on relay board. Loss of signal from control board to relay board.

127

MV 5 ERROR

Motor valve #5 did not move when commanded.

(1) Check all cables from relay PCB to Motor valves. (2) Check LED for relay

PCB#2, Shown later in this section. (3) Check relay PCB#2 incoming signal.

(4) Check relay PCB#2 output signal. (5) Switch cables to a working MV; If

MV works, replace malfunctioning MV. If MV does not work, replace or repair

cables. (6) Broken wire or cable. P1-8, P10-2, P2-8, PL5 and P2-3 not

seated properly. Pin or socket not seated in plug housing properly. Faulty SSR

on relay board. Loss of signal from control board to relay board.

128

MV 6 ERROR

Motor valve #6 did not move when commanded.

(1) Check all cables from relay PCB to Motor valves. (2) Check LED for relay

PCB#2, Shown later in this section. (3) Check relay PCB#2 incoming signal.

(4) Check relay PCB#2 output signal. (5) Switch cables to a working MV; If

MV works, replace malfunctioning MV. If MV does not work, replace or repair

cables. (6) Broken wire or cable. P1-9, P10-2, P2-9, PL6 and P2-3 not

seated properly. Pin or socket not seated in plug housing properly. Faulty SSR

on relay board. Loss of signal from control board to relay board.

129

MV 7 ERROR

Motor valve #7 did not move when commanded.

(1) Check all cables from relay PCB to Motor valves. (2) Check LED for relay

PCB#2, Shown later in this section. (3) Check relay PCB#2 incoming signal.

(4) Check relay PCB#2 output signal. (5) Switch cables to a working MV; If

MV works, replace malfunctioning MV. If MV does not work, replace or repair

cables. (6) Broken wire or cable. P1-10, P10-2, P2-10, PL7 and P2-3 not

seated properly. Pin or socket not seated in plug housing properly. Faulty SSR

on relay board. Loss of signal from control board to relay board.

130

MV 8 ERROR

Motor valve #8 did not move when commanded.

(1) Check all cables from relay PCB to Motor valves. (2) Check LED for relay

PCB#2

, Shown later in this section.

(3

) Check rela

y

PCB#2 incomin

g

si

g

nal.

131

THC CONTROL FAI

LI

ndicates a failure on the THC control board.

Replace board.

132

THC CONTROL FAIL

Indicates a failure on the THC control board.

Replace board.

150

INTERLOCK (E-STOP)

External emergency stop activated on cutting apparatus.

Reset e-stop at cutting machine.

151

SOFTWARE FAIL

This is a catch all message indicating that the software has unexpectedly failed

to

p

erform a routine o

p

eration.

Cycle power and try and continue operation.

Advertising