Power supply -6, Specifications, Power supply – Hypertherm HD4070 Rev.8 User Manual
Page 34
Advertising

SPECIFICATIONS
1
2-6
HD4070
Instruction Manual
4070.42
50.5"
1283 mm
39.4"
1001 mm
24.25"
616 mm
1068 lb
484.9 kg
34.4"
874 mm
5"
127 mm
34.9"
886 mm
15.6"
396 mm
Power Supply
General
Maximum OCV (U
0
)
311 VDC
Maximum Output Current (I
2
)
200 amps
Output Voltage (U
2
)
85 - 200 VDC
Duty Cycle Rating (X)
100% @ 40 kw, 104°F (40°C)
Ambient Temperature/Duty Cycle
Power supplies will operate between +14° and 104°F
( -10°C and +40°C)
Power Factor(cos
ϕ
)
0.98 @ 200A DC output
Cooling
Forced Air (Class F)
Input Power (Input Voltage (U
1
) X Input Current (I
1
X 1.73)
200 VAC, 3ph, 50-60 Hz, 125A
220 VAC, 3ph, 50-60 Hz, 113A
240 VAC, 3ph, 60 Hz, 103A
400 VAC CE, 3ph, 50-60 Hz, 62A
440 VAC, 3ph, 50-60 Hz, 56A
480 VAC, 3ph, 60 Hz, 52A
600 VAC, 3ph, 60 Hz, 41A
Advertising