Power supply -6, Specifications, Power supply – Hypertherm HD4070 Rev.8 User Manual

Page 34

Advertising
background image

SPECIFICATIONS

1

2-6

HD4070

Instruction Manual

4070.42

50.5"

1283 mm

39.4"

1001 mm

24.25"

616 mm

1068 lb

484.9 kg

34.4"

874 mm

5"

127 mm

34.9"

886 mm

15.6"

396 mm

Power Supply

General

Maximum OCV (U

0

)

311 VDC

Maximum Output Current (I

2

)

200 amps

Output Voltage (U

2

)

85 - 200 VDC

Duty Cycle Rating (X)

100% @ 40 kw, 104°F (40°C)

Ambient Temperature/Duty Cycle

Power supplies will operate between +14° and 104°F
( -10°C and +40°C)

Power Factor(cos

ϕ

)

0.98 @ 200A DC output

Cooling

Forced Air (Class F)

Input Power (Input Voltage (U

1

) X Input Current (I

1

X 1.73)

200 VAC, 3ph, 50-60 Hz, 125A

220 VAC, 3ph, 50-60 Hz, 113A

240 VAC, 3ph, 60 Hz, 103A

400 VAC CE, 3ph, 50-60 Hz, 62A

440 VAC, 3ph, 50-60 Hz, 56A

480 VAC, 3ph, 60 Hz, 52A

600 VAC, 3ph, 60 Hz, 41A

Advertising