MAINTENANCE

5-12

HD4070

Instruction Manual

1

U

V

W

PE

Power Measurement

Note: Check lines in the following order:

U to V
U to W
V to W
Check each line to ground. If one

line is 10% or higher than the other two,
put that leg on U.

5. Measure the voltage between the W, V and U terminals of TB1 located on the right side of the power supply.

See figure above. Also refer to the wiring diagram in Section 7, if required. The voltage between any 2 of the 3
terminals should be equal to the supply voltage. If there is a problem at this point, disconnect main power and
check connections, power cable, and fuses at line disconnect switch. Repair or replace any defective
component.

WARNING

There is line voltage at the contactor after the line disconnect switch is ON, even if the the circuit breaker

on the power supply is OFF. Use extreme care when measuring primary power in these areas. Voltages

present at the terminal block and contactors can cause injury or death.