Error codes -14, Error codes, Hd4070 error codes – Hypertherm HD4070 Rev.8 User Manual

Page 161: Warning

Advertising
background image

MAINTENANCE

5-14

HD4070

Instruction Manual

1

Error Codes

HD4070 Error Codes

Error codes are displayed at the top of screen 13. The system will clear some error codes and will then return to the
READY state. Other error codes require the operator to turn off the power supply, perform corrective maintenance
and then turn ON the power supply again. Press the HELP button to view error code number and general
description.

4070.39

13

TORCH 1

LOW PRESSURE WARNING

STAINLESS STEEL

NEW

PROCESS

NEXT

AUTO
MAN
THC

ARC
VOLT

ARC
VOLT

OVERRIDE VOLTS: 144.5 V

SET ARC VOLTS: 142.0 V

INLET GAS: H35 N2

CUTTING SPEED: 65 IPM

3/4 IN

200 AMPS

STANDOFF: 0.050 IN

++

_ _

13

CNC

TORCH 1

LOW PRESSURE WARNING

STAINLESS STEEL

NEW

PROCES

NEXT

AUTO
MAN

THC

ARC
VOLT

ARC
VOLT

OVERRIDE VOLTS: 144.5 V

SET ARC VOLTS: 142.0 V

INLET GAS: H35 N2

CUTTING SPEED: 65 IPM

3/4 IN

200 AMPS

STANDOFF: 0.050 IN

++

_ _

CNC

HELP

Plasma Process Control

BACK

ERROR CODE 3 – SUPPLY GAS PRESSURE
TOO LOW. CHECK FOR PROPER SUPPLY GAS
PRESSURE. ERROR WILL CLEAR WHEN
PRESSURE IS RESTORED TO 110-130 PSI/
7.6-9.0 BAR.

WARNING

ELECTRIC SHOCK CAN KILL

A

ll work must be performed by qualified personnel

When troubleshooting the system with the
power supply access panels removed, pull the
associated door interlock switch plunger out to
disable the door interlock error.

Advertising