Noise levels, Torch lifter requirement, Water purity requirements for coolant mixture – Hypertherm HD4070 Rev.8 User Manual

Page 45

Advertising
background image

INSTALLATION

6

3-4

HD4070

Instruction Manual

Noise levels

Acceptable noise levels as defined by national or local codes may be exceeded by this plasma system. Always
wear proper ear protection when cutting or gouging. See also Noise Protection in the Safety section of this manual.

Water Purity

Conductivity

Resistivity

Dissolved

Grains per

Water Purity

µS/cm

M

/cm

Solids

Gallon

at 77° F (25 °C)

at 77° F (25 °C)

(ppm of NaCl)

(gpg of CaCO

2

)

Pure Water
(reference only)

0.055

18.3

0

0

Maximum Purity

0.5

2

0.206

0.010

Minimum Purity

18

0.054

8.5

0.43

Max. Potable Water
(reference only)

1000

0.001

495

25

Torch Lifter Requirement

The HD4070 system requires a high-quality, motorized torch lifter with sufficient travel to cover all cutting thickness
requirements. The lifter must provide 8 inches (203 mm) of vertical travel. The unit should have the capability of
maintaining a constant speed of up to 200 ipm (5080 mm/min) with positive braking. A unit which drifts through the
stop point is not acceptable.

Water Purity Requirements for Coolant Mixture

Maintaining a low level of calcium carbonate is critical for proper performance of the torch and components in the
cooling system. Water purity should meet the requirements defined in the table below, When mixing Hypertherm
coolant (P/N 028873 - 100% propylene glycol) with water to create the appropriate coolant mixture.

Note:

If water purity exceeds maximum levels, mineral deposits may occur throughout the system.
If water purity is below minimum levels, soluble materials may leach into the coolant..

Advertising