Hypertherm HD4070 Rev.8 User Manual

Page 173

Advertising
background image

MAINTENANCE

5-26

HD4070

Instruction Manual

3

LEDN9

Signal Name

Function

LEDN9-1

Not Used

LEDN9-2

Not Used

LEDN9-3

CNC machine cable installed

Detects CNC cable. Jumper required from CNC

LEDN9-4

CNC spare input 1

LEDN9-5

CNC spare input 2

LEDN9-6

CNC plasma sync

Keeps plasma system in pre-flow (used for synchronizing
multiple systems)

LEDN9-7

CNC corner hold

THC motion stopped (at corner)

LEDN9-8

CNC system start

Cycle start (plasma start)

LEDN9-9

Gas error

Error detected in gas system

LEDN9-10

Not Used

LEDN10

Signal Name

Function

LEDN10-1

Not Used

LEDN10-2

Slave input power active

LEDN10-3

Slave missing phase detect

LEDN10-4

Slave chopper #1 temp OK

LEDN10-5

Slave chopper #2 temp OK

LEDN10-6

Slave temp/airflow OK

LEDN10-7

Slave output current OK

LEDN10-8

Slave door interlock

LEDN10-9

Not Used

LEDN10-10

Not Used

LEDN7

Signal Name

Function

LEDN7-1

CNC motion

Sends start signal to THC

LEDN7-2

Slave 80 Amp select

LEDN7-3

Slave 40 Amp select

LEDN7-4

Slave 20 Amp select

LEDN7-5

Slave 10 Amp select

LEDN7-6

Slave 1/10th current

LEDN7-7

Slave fan control

LEDN7-8

Slave contactor control

LEDN7-9

Slave DC output ON/OFF

LEDN7-10

CNC transfer

Indicates arc has transferred to work-piece

LEDN8

Signal Name

Function

LEDN8-1

THC2 cycle start

Gives signal for THC to start

LEDN8-2

Pilot arc relay

Turns pilot arc relay ON

LEDN8-3

Transfer 3

LEDN8-4

Transfer 2

Sets various transfer levels, depending on process selected

LEDN8-5

Transfer 1

LEDN8-6

Plasma int spare out

LEDN8-7

Torch #2 cooling select

Torch #2 cooling solenoid turns ON

LEDN8-8

Torch #1 cooling select

Torch #1 cooling solenoid turns ON

LEDN8-9

Pump/fan control

Large fan in power supply turns ON

LEDN8-10

Surge injection select

Selects different surge levels (normal/marking)

Advertising