4

Start Circuit Functional Schematic

Start Circuit Troubleshooting

• D2 should always be ON.
• D1 illuminates as soon as the torch fires and then will extinguish as soon as the arc transfers to the plate. If

arc transfer is immediate, the LED will not illuminate.

• If there is no arc at the torch or if the arc will not transfer:

• Turn the power to the system OFF and check for a resistance of 15 k

from H8 to H1.

• Check for a resistance of 5.5 k

across H10 and H4.

Refer to wiring diagrams. Note that the resistances will slowly increase to the above values due to
capacitance in the circuit.

• Check the junction of the D12 diode.
• Work cable connection on the cutting table is not making good contact.
• Check D2. It should be illuminated.
• Fire the torch in the air and check to be sure that D1 illuminates.
• Check the resistance across the R3 resistor. It should be 1 k

.

Chopper

Plasma Power Supply

Start Circuit

Choke

Control
Logic

IGBT

Power Resistor

ALEL Caps

Diode

Cutting

Arc

Pilot

Arc

WARNING

SHOCK HAZARD: Always use caution when servicing a power supply when plugged in and the covers are
removed. Dangerous voltages exist within the power supply which could cause injury or death.